TECHNOLOGIES

E-Mobility Heat Exchange Modules

Air heat exchanger

Air cooler

Hydrogen heat exchanger

Characteristics

  • Air cooler: Cools high-temperature dry air supply inside membrane humidifier using coolant
  • Hydrogen heat exchanger: Uses coolant to preheat hydrogen to the level required by the system

Main Performance Specifications

Category Item Technical specification
Air cooler Air operational temperature -40 ℃ ~ 180 ℃
coolant operational temperature -40 ℃ ~ 80 ℃
Air outlet temperature ≤ 85 ℃
Air pressure drop ≤15mbar
coolant pressure drop ≤80mbar
Rupture pressure ≥20Bar
Hydrogen heat exchanger System operation temperature -25 ℃ ~ 70 ℃
Operational fluid temperature -40 ℃ ~ 95 ℃
Hydrogen outlet temperature ≥55 ℃
Hydrogen pressure drop ≤12mbar
coolant pressure drop ≤20mbar
Rupture pressure ≥50Bar